GLOG-630A/4 630a manual load change over power switch

FOB Reference Price:Get Latest Price
$90.00 - $200.00 / Pieces | 1 Piece/Pieces (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Zhejiang, China (Mainland)
Brand Name:
CSQ
Model Number:
GLOG-630A/4
Max. Current:
3200A
Max. Voltage:
690V
housing:
modular design
Operating mode:
two type
Auxiliary contact:
available
Poles:
3 and 4
Use category:
AC-21, 22, 23B
certificate:
CE,CCC,,ISO9001,PICC
design:
module
Symbol window:
yes
Pollution protection:
3 grade
Brand:
OEM & ODM
Supply Ability
Supply Ability:
2000 Piece/Pieces per Week
Packaging & Delivery
Packaging Details
1, Strong export package, suitable for long distance transportation.
2, Customized package with customer's design, carton, box, and tape.
Port
Ningbo, shanghai

 

 

 

Why choose us

1.Large scale of production and conditions

****The top 10 ATS manufacture in China - more than 350 Agents in local market and more than 100 foreign clients make OEM,ODM order from us,some of them are famous brand,such as HYUNDAI.

***** We have three companys.    

Parent company is   SIQI TECHNOLOGY CO., LTD ( formerly: ZHEJIANG SIQI ELECTRIC                                             CO.,LTD), which located in Wenzhoucity of China.

Branch one--- SHANGHAI MONQE ELECTRICCO.,LTD located in Shanghai city.

Branch two ---WEIHAI SHINAIDE ELECTRIC CO.,LTD

*****  Annual sales- The total Annual sales is about USD33333333.

2.Our Promise

***** 2 years warranty(any problems because of our quality,we will give free replace or give first time service).We are always here waiting for your requirements and suggestion.

***** Provide solutions and high quality products

***** Streamline the buying and paying processes  

***** Deliver the goods to our customers all over the world with speed and precision

***** OEM and ODM is available.   

3. Sample order

***** sample order is available for quality check and market test.

4.Quick delivery

***** It usually takes about 3-5 working days for small sample order and 15-25 days for big order. 

5. payment terms

***** We usually accept all kinds of payment terms,such as:   T/T, L/C, D/P, D/A, D/D, PAYPAL,   WESTERN UNION, CASH.

 

Feedback

Feedback from our customers

There are many Objective evaluation from our customers.

Details reference to the link:http://www.aliexpress.com/store/feedback-score/818834.html

 

630a manual load change over power switch

 

Product Description

GLOG series 630a type 

 

 1.Application 

***Rated current: 125a, 160a, 200a, 250a, 400a, 630a

***Making and breaking circuit or electric isolate.

***switch conforms to IEC60947-3 and GB/T14048.3

 

2.Innovation structure:

***more compact and aesthetically

***Intergration can be installed more easier

***Easier to increase or decrease of function

 

3. Basic Specification and Main Parameters: 

 

***Operation mode: 1)Direct operation 2) outside of cabinet

 

 

 

   GLOG-63~4000A electrical properties and mechanical properties

 

 

 

4. Overall & Installation Dimension 

 

  External dimesion and installation dimension of GLOG-315~630A Load-Isolation switch

 

 

 

Specification

 

                                           External Dimension and Installation Dimension

A

B

C

D

D1

E

Φ L

J

K

N

P

R

S

T

U

Φ X

Y

F

H

GLOG-315A/3

230

240

185

50

138

116

7

210

140

145

65

32

40

5

206

10.5

36

94

20

GLOG-315A/4

290

240

185

50

138

116

7

270

140

145

65

32

40

5

206

10.5

36

94

20

GLOG-400A/3

230

240

185

50

138

116

7

210

140

145

65

32

40

5

206

10.5

36

94

20

GLOG-400A/4

290

240

185

50

138

116

7

270

140

145

65

32

40

5

206

10.5

36

94

20

GLOG-500A/3

230

260

185

50

138

116

7

210

140

145

65

40

50

6

220

12.5

37

94

20

GLOG-500A/4

290

260

185

50

138

116

7

270

140

145

65

40

50

6

220

12.5

37

94

20

GLOG-630A/3

230

260

185

50

138

116

7

210

140

145

65

40

50

6

220

12.5

37

94

20

GLOG-630A/4

290

260

185

50

138

116

7

270

140

145

65

40

50

6

220

12.5

37

94

20

 

 

6. Matters need attention

 When users test or operate please follow relative rules and pay attention to the following matters to ensure use our ATS correctly.

1)Neutral conductor N can’t be connected in wrong way, must connect reliably, otherwise ATS can’t operate properly, even burn controller and motor.

2)The protective grounding of ATS must be connected reliably to ensure safety.

3)Detection sampling signal for controller work power and main power supply is taken from Power supply side of main circuit, and work power of auxiliary connection terminal used for connect indicator is taken from main circuit, so can’t have voltage test between spare terminals (unless dismantle the secondary wires). Can have power frequency voltage test between main circuit and shell or between secondary auxiliary terminals and shell.

 

7. Simple troubleshooting

When users find fault can request professional to test and deal with. Keep Away for Safety when operate. Or contact our Specialized Service Departments.

1) Double Power are both switched on, but ATS can’t transfer automatically

  1. Check Auto/manual should be in automatic position.
  2. Check if incoming line is correct or not, if phase sequence is accordance or not, and wiring is solid and reliable or not.
  3. Check if the fuse is burned on not.

2)       Double power are both switched on, ATS standby power is switching on.

  1. Check if normal power incoming line has voltage or not.